| S2 C2
inc.
|
| Home | Triad | Direct-Push | Mobile Lab | Direct-Sensing | GIS Capabilities | Equipment | Personnel| | Downloads| |
Latest News:Posted: February 2008 S2C2 has recently been recognized as a certified Geoprobe® MIP Service Specialist.
Posted: October 2007 ASTM Method for MIP is available ASTM D7352-07
Posted: October 2007 S2C2 has Purchased a Geoprobe® 6600 truck rig.
Posted: 01 December 2005 S2C2 has successfully mapped the historic fill/native soil interface at a Brownfields site in central NJ, using a SC400 Conductivity Probe.
Posted: 01 May 2004 S2C2 was able to determine presence of metals contamination while locating the bottom of a former pond, using the Conductivity Probe. |
dIRECT-sENSING sERVICES Electrical Conductivity, MIP and FFD The number of direct-sensing technologies available to direct-push units has greatly increased in the last 10 years. S2C2 can now provide direct sensing services to determine chlorinated and non chlorinated VOCs and aromatic petroleum hydrocarbon impacts coupled with continuous soil lithology data. Direct-sensing requires competent proven operators and analysts to generate high quality data. The experience and technological know-how gained through thousands of feet of direct-sensing sampling has been extremely valuable in interpreting data. Pattern recognition is a key component to interpreting direct-sensing data. Because of this experience S2C2 has been successful at mapping historic fill/native interfaces, confining units, potential contaminant preferential pathways, and metals contamination at numerous sites throughout the urban Northeast and Mid-Atlantic states. All of S2C2’s direct-push units are capable of pushing the MIP®, FFD or Conductivity probes. Whether it requires a track mounted Geoprobe® 6620DT, a truck mounted Geoprobe® 6600 or 5410, or an ATV Bobcat® with Geoprobe®, S2C2 has the experience and tools to finish the job on-time in a variety of site conditions. Advantages of Direct Sensing • Obtain rapid VOC, Petroleum and lithologic information • Provide “Real-Time” displays of depth, conductivity, and speed • Determine thickness and lateral extent of lithologic units • Limited soil sampling required to confirm log response • No drill cuttings • Construct detailed geologic cross sections • Locate appropriate lateral and vertical placement of wells • Target zones for injection of HRC®,ORC®, etc. • Conductivity readings collected 20/secondfinish the job on-time in a variety of site conditions.
|
|
S2 C2 inc. 5 Johnson Drive, Suite 12. Raritan, NJ 08869 © 2005 |